Choose the firestop system by what passes through the opening, how large it is, whether cables will change, and the fire rating your project requires.

01
Penetrants Cables, cable trays, pipes, metal ducts or mixed services.
02
Opening size Small gaps, standard openings or large openings and shafts.
03
Future changes Will cables be added or removed later? Then choose a re-enterable system.
04
Required rating F and T ratings, and whether FM Approval or a test report is required.

Cable penetrations

Cable shafts
Cable shafts RECOMMENDED SYSTEM Firestop Composite Sheet + Elastic Firestop Sealant VC + VJ →
Cable trays through walls
Cable trays through walls RECOMMENDED SYSTEM Firestop Composite Sheet + Elastic Firestop Sealant VC + VJ →
Cable tunnel fire barriers
Cable tunnel fire barriers RECOMMENDED SYSTEM Firestop Composite Sheet + Elastic Firestop Sealant VC + VJ →
Cable trench fire barriers
Cable trench fire barriers RECOMMENDED SYSTEM Firestop Composite Sheet + Elastic Firestop Sealant VC + VJ →
Cable openings
Cable openings RECOMMENDED SYSTEM Firestop Brick + Intumescent Firestop Sealant VM + V3J →
Fire barriers between cables
Fire barriers between cables RECOMMENDED SYSTEM Firestop Brick + Intumescent Firestop Sealant VM + V3J →

Pipe, duct and electrical protection

Fire-protection pipes
Fire-protection pipes RECOMMENDED SYSTEM Inorganic Plugging Material + Elastic Firestop Sealant View products →
Water pipes
Water pipes RECOMMENDED SYSTEM Firestop Composite Sheet + Elastic Firestop Sealant View products →
Cable ducts
Cable ducts RECOMMENDED SYSTEM Fireproof Sealing Board (Coating) + Elastic Firestop Sealant View products →
Cabinet cable entries
Cabinet cable entries RECOMMENDED SYSTEM Firestop Brick + Intumescent Firestop Sealant View products →
Cable joints
Cable joints RECOMMENDED SYSTEM Fire Protection Blanket + Fire-resistant Board View products →
Cable surface protection
Cable surface protection RECOMMENDED SYSTEM VT Intumescent / V6T Ablative Cable Coating View products →
FM APPROVED SYSTEM GUIDE

Which FM design fits your opening?

If your project has… Design Main products F T
Large openings, fixed cables, simple installation 790 JH-608 + JH-607 3 Hr 1¾ Hr
Future cable changes, re-entry needed 791 JH-614 + JH-606/JH-607 2 Hr 1½ Hr
Irregular openings, many penetrants, including steel pipe 792 JH-603 3 Hr 2¾ Hr
High impact resistance, heavy-duty areas 793 JH-613 + JH-606/JH-607 3 Hr 2¾ Hr
FM Approvals Project PR461358, held by manufacturing partner Hebei Junhui Security Technology Co., Ltd.